Fuseal 45 degrees wye PP DWV 8"-12" S x S x S
The Georg Fischer Fuseal 45 degrees wye S x S x S is a heavy-duty polypropylene branch fitting engineered for large-diameter corrosive waste drainage and industrial DWV networks. Sized for 8-inch, 10-inch, and 12-inch systems, this all-socket fitting provides a smooth 45-degree lateral junction that optimizes flow dynamics and prevents sediment accumulation in gravity and low-pressure discharge lines. It delivers continuous service up to 82 degrees Celsius (180 degrees Fahrenheit) and withstands operating pressures up to 50 psi.
Technical specifications
The fitting is rated for non-pressurized gravity drainage as well as pressurized DWV service up to 50 psi, accommodating pumped discharges and vacuum drainage cycles. Its thick-walled polypropylene structure ensures dimensional stability across demanding thermal and chemical operating environments.
- Nominal diameters: 8", 10", and 12" (compatible with Schedule 40 and Schedule 80 pipes)
- Branch angle: 45 degrees lateral branch with socket x socket x socket (S x S x S) geometry
- Operating pressure: Rated up to 50 psi for electrofusion drainage systems
- Operating temperature: Continuous service up to 82 degrees C (180 degrees F); intermittent thermal peaks up to 100 degrees C (212 degrees F)
- Material formulations: Flame retardant polypropylene (PPFR) and non-flame retardant polypropylene (PPNFR)
- Chemical resistance: Immune to dilute mineral acids, concentrated alkalis, alcohols, solvents, and salt solutions
Materials and standards
Constructed from high-grade polypropylene compounds, this fitting resists electrolytic decay, galvanic reactions, scaling, and aggressive industrial effluents. The material is formulated with thermal stabilizers and UV-resistant pigments to ensure long-term structural integrity in exposed installations.
The component is manufactured to match the dimensions and tolerances of Schedule 40 and Schedule 80 polypropylene pipe lines. While the polymer offers exceptional resistance to acids, bases, and aqueous salts, strong oxidizing acids and specific chlorinated hydrocarbons should be evaluated against chemical compatibility charts prior to deployment. The flame retardant version (PPFR) is suited for above-ground and return-air plenum environments, while the non-flame retardant compound (PPNFR) provides reliable containment in underground and industrial drainage networks.
Installation and jointing
Joining is performed using Georg Fischer Fuseal LD loose coil electrofusion technology, which embeds coated resistance wire into each socket to produce a permanent, leak-tight fusion weld. This process yields homogeneous joints that equal or exceed the parent pipe strength under operating loads.
Installers must bevel pipe ends and prepare joint surfaces using recommended abrasive paper before inserting the loose heating coils into the S x S x S sockets. Electrofusion cycles are automated using the dedicated Georg Fischer Electro Plus fusion control unit, which applies automatic temperature compensation and diagnostic checks to confirm joint integrity. Proper axial alignment and clamping must be maintained throughout the fusion and cooling phases to ensure full joint sealing.
The Georg Fischer Fuseal 45 degrees wye S x S x S is a heavy-duty polypropylene branch fitting engineered for large-diameter corrosive waste drainage and industrial DWV networks. Sized for 8-inch, 10-inch, and 12-inch systems, this all-socket fitting provides a smooth 45-degree lateral junction that optimizes flow dynamics and prevents sediment accumulation in gravity and low-pressure discharge lines. It delivers continuous service up to 82 degrees Celsius (180 degrees Fahrenheit) and withstands operating pressures up to 50 psi.
Technical specifications
The fitting is rated for non-pressurized gravity drainage as well as pressurized DWV service up to 50 psi, accommodating pumped discharges and vacuum drainage cycles. Its thick-walled polypropylene structure ensures dimensional stability across demanding thermal and chemical operating environments.
- Nominal diameters: 8", 10", and 12" (compatible with Schedule 40 and Schedule 80 pipes)
- Branch angle: 45 degrees lateral branch with socket x socket x socket (S x S x S) geometry
- Operating pressure: Rated up to 50 psi for electrofusion drainage systems
- Operating temperature: Continuous service up to 82 degrees C (180 degrees F); intermittent thermal peaks up to 100 degrees C (212 degrees F)
- Material formulations: Flame retardant polypropylene (PPFR) and non-flame retardant polypropylene (PPNFR)
- Chemical resistance: Immune to dilute mineral acids, concentrated alkalis, alcohols, solvents, and salt solutions
Materials and standards
Constructed from high-grade polypropylene compounds, this fitting resists electrolytic decay, galvanic reactions, scaling, and aggressive industrial effluents. The material is formulated with thermal stabilizers and UV-resistant pigments to ensure long-term structural integrity in exposed installations.
The component is manufactured to match the dimensions and tolerances of Schedule 40 and Schedule 80 polypropylene pipe lines. While the polymer offers exceptional resistance to acids, bases, and aqueous salts, strong oxidizing acids and specific chlorinated hydrocarbons should be evaluated against chemical compatibility charts prior to deployment. The flame retardant version (PPFR) is suited for above-ground and return-air plenum environments, while the non-flame retardant compound (PPNFR) provides reliable containment in underground and industrial drainage networks.
Installation and jointing
Joining is performed using Georg Fischer Fuseal LD loose coil electrofusion technology, which embeds coated resistance wire into each socket to produce a permanent, leak-tight fusion weld. This process yields homogeneous joints that equal or exceed the parent pipe strength under operating loads.
Installers must bevel pipe ends and prepare joint surfaces using recommended abrasive paper before inserting the loose heating coils into the S x S x S sockets. Electrofusion cycles are automated using the dedicated Georg Fischer Electro Plus fusion control unit, which applies automatic temperature compensation and diagnostic checks to confirm joint integrity. Proper axial alignment and clamping must be maintained throughout the fusion and cooling phases to ensure full joint sealing.
| Size | SKU | U.M. |
Price
incl. 21% VAT
VAT is calculated at checkout. It depends on who is buying (private person or company) and where the order is shipped, so the final rate may differ from the one shown here.
|
Availability | Add To Cart |
|---|---|---|---|---|---|
|
Thread
8
|
216308F | pcs | On Request |
Ships in 24 hours
Ships in 7-10 days
Ships in 10-15 days
Max stock reached
Please call
|
|
|
Thread
8
|
526308F | pcs | On Request |
Ships in 24 hours
Ships in 7-10 days
Ships in 10-15 days
Max stock reached
Please call
|
|
|
Thread
10
|
216305F | pcs | On Request |
Ships in 24 hours
Ships in 7-10 days
Ships in 10-15 days
Max stock reached
Please call
|
|
|
Thread
10
|
526305F | pcs | On Request |
Ships in 24 hours
Ships in 7-10 days
Ships in 10-15 days
Max stock reached
Please call
|
|
|
Thread
12
|
216300F | pcs | On Request |
Ships in 24 hours
Ships in 7-10 days
Ships in 10-15 days
Max stock reached
Please call
|
|
|
Thread
12
|
526300F | pcs | On Request |
Ships in 24 hours
Ships in 7-10 days
Ships in 10-15 days
Max stock reached
Please call
|
|