A collection of Georg Fischer DryLoc pH/ORP electrodes, a digital flow controller, and signal modules.

DryLoc Signet 2724-2726 pH/ORP Sensor Electrode

  Datasheet (PDF) |   Datasheet (PDF) |   Datasheet (PDF) |   Datasheet (PDF) |   Datasheet (PDF)

The Georg Fischer Signet 2724-2726 series provides robust pH and ORP electrode solutions designed for industrial water treatment, chemical processing, and environmental monitoring systems. BigWeld, an authorised Georg Fischer distributor, supplies these high-precision sensors engineered with the patented DryLoc connector, featuring gold-plated contacts and a mechanical interlock that protects internal electronics from moisture, dirt, and chemical attack in harsh process environments.

Technical specifications

Georg Fischer Signet 2724-2726 electrodes integrate precision sensing glass and temperature elements to deliver reliable, thermally compensated analytical measurements across diverse process streams. The sensors couple directly to dedicated transmitters to maintain signal integrity over long operating cycles.

  • Sensing element options: flat glass pH, bulb glass pH, or flat platinum ORP surface.
  • Specialised glass options: hydrofluoric acid resistant (HF) and low conductivity (LC) glass formulations.
  • Temperature compensation: integrated PT1000 or 3 kOhm RTD element for automated thermal correction.
  • Electrical connection: patented DryLoc connector with corrosion-resistant gold-plated contacts.
  • Reference junction: large-area porous UHMW-PE junction with an extended electrolyte path.
  • Signal transmission: compatible with Signet 2750 sensor electronics and Signet 2760 preamplifiers.

Materials and standards

Constructed with an injection-moulded polyphenylene sulfide (PPS) Ryton body, these electrodes provide exceptional resistance to aggressive chemicals, solvents, and mechanical abrasion. The inert construction materials prevent degradation in demanding industrial streams and ensure stable chemical compatibility.

The reference system utilizes ultra-high-molecular-weight polyethylene (UHMW-PE) to create a porous barrier that resists fouling and impedes chemical poisoning of the internal electrolyte. The precision glass formulations maintain electrical stability under chemical exposure, while gold-plated contacts ensure corrosion-free electrical conductivity. These assemblies are manufactured under ISO 9001 quality management and ISO 14001 environmental management standards to ensure repeatable industrial measurement performance.

Installation and jointing

Georg Fischer Signet 2724-2726 electrodes mount via an external 3/4 inch NPT or ISO 7-1 R 3/4 male thread for straightforward installation directly into process piping or immersion assemblies. The patented DryLoc keyway ensures correct alignment and quick sensor replacement without disconnecting wiring back to the transmitter.

The threaded body fits standard pipe tees, Signet installation fittings, or submersible sensor housings, accommodating both in-line flow and tank monitoring configurations. Technicians can connect the DryLoc electrode directly to a Signet 2750 sensor electronic module or a Signet 2760 preamplifier, allowing direct communication with Signet 8750, 8900, 9900, and 9950 multi-parameter controllers. Proper installation requires threading the PPS body with suitable sealant into compatible fittings while ensuring that the sensing glass tip remains fully submerged during operation.

  Datasheet (PDF) |   Datasheet (PDF) |   Datasheet (PDF) |   Datasheet (PDF) |   Datasheet (PDF)

The Georg Fischer Signet 2724-2726 series provides robust pH and ORP electrode solutions designed for industrial water treatment, chemical processing, and environmental monitoring systems. BigWeld, an authorised Georg Fischer distributor, supplies these high-precision sensors engineered with the patented DryLoc connector, featuring gold-plated contacts and a mechanical interlock that protects internal electronics from moisture, dirt, and chemical attack in harsh process environments.

Technical specifications

Georg Fischer Signet 2724-2726 electrodes integrate precision sensing glass and temperature elements to deliver reliable, thermally compensated analytical measurements across diverse process streams. The sensors couple directly to dedicated transmitters to maintain signal integrity over long operating cycles.

  • Sensing element options: flat glass pH, bulb glass pH, or flat platinum ORP surface.
  • Specialised glass options: hydrofluoric acid resistant (HF) and low conductivity (LC) glass formulations.
  • Temperature compensation: integrated PT1000 or 3 kOhm RTD element for automated thermal correction.
  • Electrical connection: patented DryLoc connector with corrosion-resistant gold-plated contacts.
  • Reference junction: large-area porous UHMW-PE junction with an extended electrolyte path.
  • Signal transmission: compatible with Signet 2750 sensor electronics and Signet 2760 preamplifiers.

Materials and standards

Constructed with an injection-moulded polyphenylene sulfide (PPS) Ryton body, these electrodes provide exceptional resistance to aggressive chemicals, solvents, and mechanical abrasion. The inert construction materials prevent degradation in demanding industrial streams and ensure stable chemical compatibility.

The reference system utilizes ultra-high-molecular-weight polyethylene (UHMW-PE) to create a porous barrier that resists fouling and impedes chemical poisoning of the internal electrolyte. The precision glass formulations maintain electrical stability under chemical exposure, while gold-plated contacts ensure corrosion-free electrical conductivity. These assemblies are manufactured under ISO 9001 quality management and ISO 14001 environmental management standards to ensure repeatable industrial measurement performance.

Installation and jointing

Georg Fischer Signet 2724-2726 electrodes mount via an external 3/4 inch NPT or ISO 7-1 R 3/4 male thread for straightforward installation directly into process piping or immersion assemblies. The patented DryLoc keyway ensures correct alignment and quick sensor replacement without disconnecting wiring back to the transmitter.

The threaded body fits standard pipe tees, Signet installation fittings, or submersible sensor housings, accommodating both in-line flow and tank monitoring configurations. Technicians can connect the DryLoc electrode directly to a Signet 2750 sensor electronic module or a Signet 2760 preamplifier, allowing direct communication with Signet 8750, 8900, 9900, and 9950 multi-parameter controllers. Proper installation requires threading the PPS body with suitable sealant into compatible fittings while ensuring that the sensing glass tip remains fully submerged during operation.

Variants, prices and availability
Size SKU U.M.
Price
incl. 21% VAT
Availability Add To Cart
incl. 21% VAT