ABS Pipe PN16 d20-d25

ABS Pipe PN16 d20-d25

Material: ABS PN: 16 Bar

  Datasheet (PDF) |   Product Range | Instructional Video

Georg Fischer (GF Piping Systems) metric ABS pressure pipe PN16 covers outer diameters d20 mm and d25 mm, rated 16 bar at 20 degrees C in accordance with EN 15493. BigWeld, an authorised Georg Fischer distributor, supplies the pipe in 5,000 mm lengths with plain ends for solvent cement jointing, for chilled water loops, industrial cooling circuits and water treatment installations.

Technical specifications

Both diameters share a 2.3 mm wall thickness and a nominal pressure of 16 bar at 20 degrees C, so the two sizes behave identically in terms of pressure class and differ only in bore and linear weight.

  • Standard: EN 15493, metric pressure specification
  • Nominal pressure: PN16, 16 bar at 20 degrees C
  • Dimensions: d20 mm with 15.4 mm bore, d25 mm with 20.4 mm bore
  • Wall thickness: 2.3 mm, uniform across d20 and d25
  • Linear weight: 0.152 kg/m at d20 mm, 0.195 kg/m at d25 mm
  • Material and colour: acrylonitrile butadiene styrene (ABS), grey RAL 7001

The bore stays smooth throughout the service life of the installation, which limits scale build-up and encrustation, keeps friction losses low and helps hold volumetric flow and pump duty stable.

Applications

The ABS range is used for cooling, chilled water, water treatment, marine and drinking water duties, where its impact strength at low operating temperatures is the deciding property.

In building services and process plant, the d20 and d25 sizes typically form the final distribution legs between chillers, air handling units, fan coils and secondary cooling skids, as well as glycol circuits and instrument and dosing lines in water treatment. ABS remains ductile at sub-zero temperatures, where more rigid thermoplastics become brittle, and it neither corrodes externally nor tuberculates internally.

Installation and jointing

Pipes are delivered with plain ends and are joined by solvent cementing into ABS solvent cement fittings, unions, flange adaptors and valves from the same Georg Fischer range.

Surfaces are prepared with Tangit PVC-U/PVC-C/ABS cleaner and bonded with Tangit ABS solvent cement, supplied alongside the pipe together with the matching solvent cementing tools. Lines are carried on PP or PE black UV-resistant pipe clips, and flanged connections use PP-GF, PP-steel or steel backing flanges with EPDM or FKM gaskets. The low linear weight of these two sizes keeps support spacing, handling and prefabrication straightforward on site.

  Datasheet (PDF) |   Product Range | Instructional Video

Georg Fischer (GF Piping Systems) metric ABS pressure pipe PN16 covers outer diameters d20 mm and d25 mm, rated 16 bar at 20 degrees C in accordance with EN 15493. BigWeld, an authorised Georg Fischer distributor, supplies the pipe in 5,000 mm lengths with plain ends for solvent cement jointing, for chilled water loops, industrial cooling circuits and water treatment installations.

Technical specifications

Both diameters share a 2.3 mm wall thickness and a nominal pressure of 16 bar at 20 degrees C, so the two sizes behave identically in terms of pressure class and differ only in bore and linear weight.

  • Standard: EN 15493, metric pressure specification
  • Nominal pressure: PN16, 16 bar at 20 degrees C
  • Dimensions: d20 mm with 15.4 mm bore, d25 mm with 20.4 mm bore
  • Wall thickness: 2.3 mm, uniform across d20 and d25
  • Linear weight: 0.152 kg/m at d20 mm, 0.195 kg/m at d25 mm
  • Material and colour: acrylonitrile butadiene styrene (ABS), grey RAL 7001

The bore stays smooth throughout the service life of the installation, which limits scale build-up and encrustation, keeps friction losses low and helps hold volumetric flow and pump duty stable.

Applications

The ABS range is used for cooling, chilled water, water treatment, marine and drinking water duties, where its impact strength at low operating temperatures is the deciding property.

In building services and process plant, the d20 and d25 sizes typically form the final distribution legs between chillers, air handling units, fan coils and secondary cooling skids, as well as glycol circuits and instrument and dosing lines in water treatment. ABS remains ductile at sub-zero temperatures, where more rigid thermoplastics become brittle, and it neither corrodes externally nor tuberculates internally.

Installation and jointing

Pipes are delivered with plain ends and are joined by solvent cementing into ABS solvent cement fittings, unions, flange adaptors and valves from the same Georg Fischer range.

Surfaces are prepared with Tangit PVC-U/PVC-C/ABS cleaner and bonded with Tangit ABS solvent cement, supplied alongside the pipe together with the matching solvent cementing tools. Lines are carried on PP or PE black UV-resistant pipe clips, and flanged connections use PP-GF, PP-steel or steel backing flanges with EPDM or FKM gaskets. The low linear weight of these two sizes keeps support spacing, handling and prefabrication straightforward on site.

Variants, prices and availability
Size SKU Property U.M.
Price
incl. 21% VAT
Availability Add To Cart
D 16 mm
169017080
Material: ABS
PN: 16 Bar
m €3.80
Ships in 24 hours Ships in 7-10 days Ships in 10-15 days Max stock reached Please call
D 20 mm
169017081
Material: ABS
PN: 16 Bar
m €7.48
Ships in 24 hours Ships in 7-10 days Ships in 10-15 days Max stock reached Please call
D 25 mm
169017082
Material: ABS
PN: 16 Bar
m €11.39
Ships in 24 hours Ships in 7-10 days Ships in 10-15 days Max stock reached Please call
incl. 21% VAT
SKU: 169017080
D: 16 mm
Ships in 24 hours
€3.80 / m
SKU: 169017081
D: 20 mm
Ships in 24 hours
€7.48 / m
SKU: 169017082
D: 25 mm
Ships in 24 hours
€11.39 / m